Products

  1. TOP
  2. Products
  3. DeviceGateway
  4. List of Support Devices

List of Support Devices

Here is a list of Devices that can be connected with DeviceGateway.

PLC(Programal Controller)

MITSUBISHI*

Series CPU Ethernet Other
MELSEC iQ-R R120/32/16/08(P)
R04
Built-in Ethernet Port
RJ71EN71
RJ71C24(-R2/R4)
MELSEC iQ-F FX5U(C/J) Built-in Ethernet Port  
MELSEC-Q
(Universal high-speed)
Q26/13/06/04/03UDV Built-in Ethernet Port
QJ71E71-100/B2/B5
QJ71C24N(-R2/R4)
MELSEC-Q
(Universal)
Q100/50UDEH
Q26UD(E)H
Q20/13/10/06/04/03UD(E)H
Q02/01/00U(J)
Built-in Ethernet Port
QJ71E71-100/B2/B5
MELSEC-Q
(Prosess)
Q26/13/06/04UDPV
Q25/12/06/02PH
QJ71E71-100/B2/B5
MELSEC-Q
(Redundant)
Q25/12PRH
MELSEC-Q
(High performance)
Q25/12/06H, Q02(H)
MELSEC-Q
(Basic)
Q01, Q00(J)
MELSEC-Q
(C language contller)
Q24DHCCPU-V
Q12DCCPU
Q06CCPU-V
Built-in Ethernet Port  
MELSEC-Q
( Motion contller)
Q170M, Q172D(S)CPU(-S1)
Q173D(S)CPU(-S1)
MELSEC-L L26CPU-(P)BT
L06CPU(-P)
L02(S)CPU(-P)
Built-in Ethernet Port
LJ71E71-100
LJ71C24(-R2)
L6ADP-R2/R4
MELSEC-FX FX3S/U/UC/G/GC
FX2(N/2NC/2C)
FX1(S/N/NC), FX0(S/N)
FX3U-ENET(-L)
FX3U-ENET-ADP
FXxx-232/485-BD
FXxx-232/485ADP(-MB)
MELSEC-QnA Q4A(R)
Q3A
Q2A(S/SH)(-S1)
A(1S)J71QE71(N)-T
A(1S)J71QE71(N)-B2/B5
AJ71QC24(N)(-R2/R4)
A1SJ71QC24(N)(-R2)
MELSEC-A A4U, A3(N/A/U)
A2(N/A/U)(S/SH)(-S1)
A1(N)(S/SH)
AJ71E71(-S3)
A(1S)J71E71(N)-T
A(1S)J71E71(N)-B2/B5
A(1S)J71UC24
AJ71C24-S8

* When using Bluetooth Beacon or Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

OMRON*

Series CPU Ethernet Other
SYSMAC-NX NX701 Built-in Ethernet Port  
SYSMAC-NJ NJ101, NJ301, NJ501 Built-in Ethernet Port
CJ1W-EIP21
SYSMAC-CJ CJ2H,CJ2M
CJ1G, CJ1H, CJ1M
Built-in Ethernet Port
CJ1W-ETN11/21
CJ1W-EIP21
Built-in Serial Port
CJ1W-SCU42/32/22
CJ1W-SCU41/31(-V1)
CJ1W-SCU21(-V1)
SYSMAC-CS CS1G,CS1H,CS1D CS1W-ETN21/11/01
CS1W-EIP21
CS1D-ETN21D
Built-in Serial Port
CS1W-SCU31/21(-V1)
CS1W-SCB41/21(-V1)
SYSMAC-CP CP1E
CP1L(-EM/EL),CP1H
Built-in Ethernet Port
CP1W-ClF41
CP1L-ETN
CJ1W-ETN21/EIP21
CP1W-CIF12/11/01
CJ1W-SCU41/31(-V1)
CJ1W-SCU21(-V1)
SYSMAC-CV CVM1(D),CV2000
CV1000,CV500
CV500-ETN01 Built-in Serial Port
CV500-LK201
SYSMAC-C C200H,CQM1(H)
CPM1/2,C2000H,C1000H
  Built-in Serial Port
C500-LK203/201/103/101
C200H-LK202/201/101
C120-LK202/201/101
SYSMAC-NSJ NSJ Built-in Ethernet Port
NSJW-ETN21
 

* When using Bluetooth Beacon or Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

YOKOGAWA

Series CPU Ethernet Other
e-RT3 RP71-R Built-in Ethernet Port
LE12-1T
 
FA-M3V F3SP71-4S/N
F3SP76-7S/N
Built-in Ethernet Port
F3LE12/11/01-0T
 
FA-M3R F3SP67-6S
F3SP66-4S
F3SP59-7S
F3SP58-6H/S
F3SP53-4H/S
F3SP38-6N/S
F3SP35-5N
F3SP28-3S/N
F3SP25-2N
F3SP22-0S
F3SP21-0N
F3SP08/05-0P
F3LE12-0T/1T
F3LE11-0T/1T
F3LE01-0T/1T/5T
 

JTEKT

Series CPU Ethernet Other
TOYOPUC-Plus Plus CPU Built-in Ethernet Port
Plus EX(2)
 
TOYOPUC-PC10 PC10G(E)
PC10P
Built-in Ethernet Port
EN-I/F(-T)
FL/ET-net-5
FL/ET-T-V2(H)
2PORT-EFR
 
TOYOPUC-PC3J PC3JG-P
PC3J(L/D/M/NM/NF)-CPU
MULTI-GW
EN-I/F(-T)
FL/ET-net-5
FL/ET-T-V2(H)
2PORT-EFR
 
TOYOPUC-PC2J PC2J(C/S/R)
PC2J16(R/H/PR/HR)
EN-I/F(-T)
FL/ET-net-5
FL/ET-T-V2(H)
 

HITACHI

Series CPU Ethernet Other
HX* HX-CP1S08(M)/
HX(C)-1H16(M)
Built-in Ethernet Port  
EH150-EHV EHV-CPU128/64/32/16 Built-in Ethernet Port
EH-ETH(2)
EH150 EH-CPU548/516/316A
EH-CPU208A/104A
EH-ETH(2)
H H-4010/2002/1002
H-702/302/252
LAN-ETH(2)

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

SHARP

Series CPU Ethernet Other
SATELLITE JW-300 JW-311CU/312CU/321CU
JW-322CU/331CU/332CU
JW-341CU/342CU/352CU
JW-362CU
JW-300/25T/255CM  
SATELLITE JW-30H JW-31CUH/H1
JW-32CUH/H1
JW-33CUH/H1
CUH2,CUH3
SATELLITE JW-20H JW-21CU/22CU
SATELLITE JW-100H JW100/100H/100CUH JW-50CM/51CM
SATELLITE JW-70H JW70/70H
SATELLITE JW-50H JW50/50H
J-board Z-500 Z-511J/512J Z339J
J-board Z-300 Z-311J/312J

FUJI

Series CPU Ethernet Other
MICREX-SX SPH5000 NP1PU1-512H Built-in Ethernet Port
NP1L-ET1/2
NP1L-RS1/2/3/4/5
MICREX-SX SPH3000 NP1PU-48E/256E
NP1PU2-048E
MICREX-SX SPH2000 NP1PM-48R/48E/256E/256H
MICREX-SX SPH300EX NP1PS-74D
MICREX-SX SPH300 NP1PS-32(R)/74(R)/
117(R)
NP1PS-245
MICREX-SX SPH200 NP1PH-08/16
MICREX-F F150 FPU150S/152S/154S FFU170B FFU120B
MICREX-F F140 FPU140S
MICREX-F F120 FPU120S
MICREX-F F70 F70(S) NC1L-ET1 NC1L-RS2/4
MICREX-F F55 F55   NV1L-RS2
MICREX-F F50 F50 Built-in Serial Port

PANASONIC *1

Series CPU Ethernet Other
FP0H FP0H C32ET/C32EP Built-in Ethernet Port AFP7CC(S1/S2/M1/M2)
AFP7CCS1M1
FP7 FP7CPS 4E/3E Built-in Ethernet Port AFP7CC(S1/S2/M1/M2)
AFP7CCS1M1
Built-in Serial Port
FP2 FP2(SH) FP2 ET-LAN(2) >Built -in Serial Port
AFPCCS2
FP2 -MCU/CCU
FP-X FP-X C60/30/
14 R/T/P(D)
FP-X COM5 FP-X COM1/2/3/4/5/6
FPΣ *2 FPΣ   AFPG801/802/806
FP0R *2 FP0R   Built-in Serial Port
FP-e *2 FP-e
Web Datalogger Unit AFL1200 Built-in Ethernet Port  

*1 Use "Modbus Connection" to connect with Panasonic FP series via serial communication.
*2 When using Bluetooth Beacon or Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

KEYENCE

Series CPU Ethernet Serial
KV-8000 KV-8000 Built-in Ethernet Port
KV-XLE02
KV-LE21V/EP21V
KV-LE20V
 
KV-7000 KV-7500/7300
KV-5000 KV-5500/5000
KV-3000 KV-3000
KV-1000 KV-1000 KV-XLE02
KV-LE20/A
KV-EP21V
KV-700 KV-700
KV Nano KV-Nano KV-NC1EP

* Use "Modbus Connection" to connect with Panasonic FP series via serial communication.

TOSHIBA

Series CPU Ethernet Other
nv(type1) PU811 EN811/EN821  
nv(type1 light) PUM11/12/14
V(S3) S3PU65A,S3PU55A,S3PU45A EN711/721/731
EN741/751(A)/761
V(S2) S2PU82,S2PU72A,S2PU72D EN611/621/631/641
EN651(A)/661
V(S2T) PU672T,PU662T EN611/631/651A
PROSEC T(T3H) PU325H,PU326H EN311
PROSEC T(T2N) PU235N,PU245N Built-in Ethernet Port

YASKAWA

Series CPU Ethernet Other
MP3300 CPU-301,CPU-302 内蔵Ethernetポート
218IF-01/02
 
MP3200 CPU-201,CPU-202
MP2400 MP2400
MP2300 MP2310,MP2300(S)
MP2200 MP2200
MP900 MP920 218IFA

IDEC*

Series CPU Ethernet Other
MicroSmart FC5A-D16RK1/D16RS1
FC5A-D32K3/D32S3
FC5A-C10R2(D/C)
FC5A-C16R2(D/C)
FC5A-C24R2(D/C)
Built-in Ethernet Port Built-in Serial Port
FC5A-SIF2/4
FC4A-HPC3

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

KOYO*

Series CPU Ethernet Other
DirectLOGIC 05 DL05 H0-ECOM100 D0-DCM
DirectLOGIC 06 DL06
DirectLOGIC 205 D2-240,D2-250,D2-260 Built-in Ethernet Port
H2-ECOM/EBC100
D2-DCM
DirectLOGIC 305 D3-340,D3-350   Built-in Serial Port
DirectLOGIC 405 D4-450
SU SU-5/5E/6B/5M/6M/6H   Built-in Serial Port
U-01DM
KOSTAC SZ SZ-4/4M  
KOSTAC S SG-8B   U-01DM
KOSTAC PZ PZ3   Built-in Serial Port
KOSTAC SJ SJ-00DD1/2-D
SJ-00DR/AR-D
SJ-02DD1/2-D
SJ-02DR-D
SJ-30DD1-D
Built-in Ethernet Port Built-in Serial Port
T1K T1K-Modbus T1H-EBC100 Built-in Serial Port
T1H-CTRIO

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

DELTA*

Series CPU Ethernet Other
AH500 AH500 AH10EN-5A  
DVP-EH DVP-EH2/3 DVPENE01-SL Built-in Serial Port
DVP-SV DVP-SV(2)
DVP-SE DVP-SE Built-in Ethernet Port
DVP-MC DVP-MC
DVP-EX DVP-EX(2)  
DVP-ES DVP-ES(2)
DVP-EC DVP-EC3
DVP-SX DVP-SX(2)
DVP-SA DVP-SA(2)
DVP-SS DVP-SS(2)
DVP-SC DVP-SC
DVP-PM DVP-PM

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

3S*

Series CPU Ethernet Other
CoDeSys (geeral PC) Built-in Ethernet Port Built-in Serial Port

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

ROCKWELL

Series CPU Ethernet Other
GuardLogix 5570 1756-ENBT
1756-EN2T
 
ControlLogix 5550/5553/5555/5561/
5562/5563/5572/5573/
5574/5575/5580
CompactLogix 5320/5323/5330/5331/
5332/5335/5345/5370/
5380/5400
Built-in Ethernet/IP Port
1769-L32E/1769-L33ER
1769-L35E/1768-ENBT
FlexLogix 5433/5434
DriveLogix 5720/5730 1788-ENBT
Micro800 2080-LC20-* (Micro820)
2080-LC50-* (Micro850)
2080-L50E-* (Micro850)
2080-LC70-* (Micro870)
2080-L70E-* (Micro870)
Built-in Ethernet/IP Port
MicroLogix 1400 1766-L32* Built-in Ethernet/IP Port
MicroLogix 1100 1763-L16* Built-in Ethernet/IP Port
SLC500(Series B and later) SLC5/01
SLC5/02
SLC5/03
SLC5/04
1761-NET-ENI
SLC5/05 Built-in Ethernet/IP Port
1761-NET-EN

SIEMENS

Series CPU Ethernet Other
SIMATIC S7-1500 CPU 1511/1513-1 PN
CPU 1515-2 PN
CPU 1516(F)-3 PN/DP
CPU 1518(F)-4 PN/DP
Built-in Ethernet Port  
SIMATIC S7-1200 CPU 1211/1212
CPU 1214C/1215C/
1217C
SIMATIC S7-400H CPU 412-3H,CPU 414/417-4H CP443-1
SIMATIC S7-400 CPU 412-1/2
CPU 417-4
CPU 414-2/3 (PN/DP)
CPU 416-2/3 (PN/DP)
SIMATIC S7-300 CPU 312/314/CPU 315-2 (PN/DP)
CPU 317-2 (PN/DP)
SIMATIC S7-200 CPU 222 CP243-1
SIMATIC WinAC WinAC RTX Built-in Ethernet Port

GE*

Series CPU Ethernet Other
90-30 IC693CPU311/IC693CPU313
IC693CPU321/IC693CPU323
IC693CPU331/IC693CPU340
IC693CPU341/IC693CPU350
IC693CPU351/IC693CPU352
IC693CPU360/IC693CPU363
IC693CPU364/IC693CPU374
IC693CSE311/IC693CSE313
IC693CSE323/IC693CSE331
IC693CSE340
  Power Unit built-in
Serial port

* When using Bluetooth Beacon or Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

Remote I/O System

MG*

Series CPU Ethernet Other
Remote I/O R1 R1   RZMS-U9
R1M(S)-GH3/GH/J3/A1/D1/P4
Remote I/O R3 R3 R3-NE1 R3-NM1/R3-NM3
Remote I/O R5 R5(H) R5-NE1 R5-NM1
Remote I/O R6 R6 R6-NE1/R6-NE2 R6-NM1/R6-NM2
Remote I/O R7 R7E Built-in Ethernet Port Built-in Serial Port
Remote I/O R8 R8   R8-NM1
TC10 TC10   TC10EM-A-M2
TC10NM-A-M2
Loop Controller SC200,SC210 Built-in Ethernet Port  
Tower Light PATLABOR IT60(W1/RE)
Data Logger DL8
DL30
Tablet Recorder TR30-G
BACnet Controller BA3-CB1 Built-in Ethernet Port  

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

ANYWIRE*

Series CPU Ethernet Other
DB A40 AG428-ES/EC
AG413-E1
Built-in Ethernet Port  

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

WAGO*

Series CPU Ethernet Other
I/O System 750-341/342/352
750-841/842/843/873/881
Built-in Ethernet Port  
750-312/314/315/316
750-812/814/815/816
  Built-in Serial Port
750-830 Built-in Ethernet Port  

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

MTT*

Series CPU Ethernet Other
Alchis MRH-T each modules MRH-T-NMT1  

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

PHOENIX CONTACT

Series CPU Ethernet Other
AXL F BK AXL F BK ETH*1 Built-in Ethernet Port  
AXL F BK EIP*2
AXL E*2 AXL E EIP

*1 Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.
*2 Accessible by EtherNet/IP communication function.

COMTROL*

Series CPU Ethernet Other
IO-Link Master Gateway
Modbus TCP
IO-Link Master 4-EIP
IO-Link Master DR-8EIP
IO-Link Master 8-EIP
Built-in Ethernet Port  

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

NC(Numerical Control)Equipment

FANUC*1*2

Series CPU Ethernet Other
Series 0(i) - - Built-in Serial Port
(DPRNT communication)
Series 0(i) -MODEL B/C/D/F -
Series 0(i) -MODEL Mate
-MODEL D
-
Series 0(i) -PD -

Series 15(i)/150(i)/16(i)/160(i)/18(i)180(i)/20(i)/21(i)/210(i)
-MODEL A/B

-
Series 16(i)/160(i)/18(i)/180(i)
-MODEL P/W
-
Series 16(i)/160(i) MODEL L -
Series 30(i)/31(i)/32(i)
-MODEL A/B
-
Series 35(i) -MODEL B -
Series 30(i)/31(i) -L MODEL B -
Series 30(i)/31(i) -P MODEL B -
Series 31(i) -W MODEL A -
Power Mate-D/F/H -
Power Mate-I MODEL D/H -
Power Motion(i) -MODEL A -

*1 Accessing to FUNUC CNC and Mitsubishi CNC is limited to models that can use the DPRNT function.
*2 When using Bluetooth Beacon or Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

MITSUBISHI*1*2

Series CPU Ethernet Other
M800/M80/E80 - - Built-in Serial Port
(DPRNT communication)
M700V/M70V/E70 -
M700/M70 -
C80 -
C70 -
M600 -
M60/60S -
E60/E68 -
C6/C64/C64T -

*1 Accessing to FUNUC CNC and Mitsubishi CNC is limited to models that can use the DPRNT function.
*2 When using Bluetooth Beacon or Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

Shibaura Machine*1*2

Series CPU Ethernet Other
TOSNUC T-PX200 ※2 - Built-in Ethernet Port Built-in Serial Port
TOSNUC T-PX100 -
TOSNUC T-999 -
TOSNUC T-888,T-888.2 - -
Tcmini TC9-00 -
Tcmini TC7-00/01/02 -
Tcmini TC6-00 -
Tcmini TC5-02/03 -
Tcmini TC3-00/01/P01/02 -

*1 Please confirm to Shibaura Machine whether your machine tool has connectivity.
*2 When using Bluetooth Beacon or Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

Machine Tool

MITSUBISHI*

Series CPU Ethernet Other
MV Series - Built-in Ethernet Port  
MP Series -
MX Series -
NA Series -
BA Series -
PA Series -
FA Series -
QA Series -
SV-P Series -
EA Series -
MA2000 -
VA Series -
SH Series -
VH Series -

* Accessible by MITSUBISHI EDM Ethernet or MTConnect communication function.

MAZAK*

Series CPU Ethernet Other
INTEGREX series etc   MTConnect Agent  

* Accessible by MTConnect communication function.

Protocol Convertor for Machine Tools

silex*

Series CPU Ethernet Other
FBR-100AN FBR-100AN Built-in Ethernet Port  

* Accessible by MTConnect communication function.

Motion / Robot Controller

YAMAHA

Series CPU Ethernet Other
RCX RCX340 Built-in Ethernet Port  
RCX-Studio

IAI*2

Series CPU Ethernet Other
ACON*1 ACON-CB/CGB/CYB/PLB/POB/
CA/C/CG/PL/PO/SE/CY
  Built-in Serial Port
DCON*1 DCON-CB/CGB/CYB/PLB/POB/CA
PCON*1 PCON-CA/CFA/CB/CGB/CFB/CGFB/CYB/
PLB/POB/C/CG/CF/PL/PO/SE/CY
SCON*1 SCON-CB/CGB/CB-F/CA/CAL/CGAL/C
RSEL G   Built-in Serial Port
X-SEL P/Q/PCT/QCT/PX/QX/R/S/RX/SX/RXD/SXD/
RA/SA/RAX/SAX/RAXD/SAXD
TT TTA
SSEL SSEL
ASEL ASEL
PSEL PSEL
MSEL PC/PG/PCF/PGF/PCX/PGX

*1 Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.
*2 When using Bluetooth Beacon or Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

SANYO DENKI*

Series CPU Ethernet Other
SANMOTION C SMC100 A / B Built-in Ethernet Port  

* Accessible by EtherNet/IP communication function.

Display Panel

HAKKO*

Series CPU Ethernet Other
MONITOUCH V815 / 812 / 810 / 808 / 806
V715 / 712 / 710 / 708
Built-in Ethernet Port Built-in Serial Port
V608 / 606 GT16/15/14

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

Vision Sensor

COGNEX*

Series CPU Ethernet Other
In-Sight In-Sight Micro/5000/EZ Built-in Ethernet Port  

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

BACnet Unit

MG

Series CPU Ethernet Other
BACnet Controller BA3-CB1 Built-in Ethernet Port  

UNITEC

Series CPU Ethernet Other
BACnet Unit for Series< MELSEC (MELSEC-Q series CPU) BAQ08V  
BACnet Unit for LonWorks (LonWorks unit) BL750
BACnet Unit for Multi-Connection (MELSEC / SYSMAC / MODBUS ) BP750-PM

Monitoring Product/Power Supply

OMRON

Series CPU Ethernet Other
Monitoring Product K6CM *1*2 - Modbus communication
K6CM-CI2MA-EIP
K6CM-CI2MD-EIP
K6CM-CIMA-EIP
K6CM-CIMD-EIP
K6CM-VBMA-EIP
K6CM-VBMD-EIP
K6CM-ISMA-EIP
K6CM-ISMD-EIP
- Ethernet/IP communication
K6CM-CI2MA-EIP
K6CM-CI2MD-EIP
K6CM-VBMA-EIP
K6CM-VBMD-EIP
Built-in Ethernet Port  
Monitoring Product K6PM*2 K6PM-THMD-EIP
Power Supply*1 S8VK-X
Motor monitoring equipment K7DD   Built-in Serial Port

*1 Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.
*2 Accessible by EtherNet/IP communication function.

Meter

AZBIL

Series CPU Ethernet Other
Instrumentation network NX-S01/11/12/21
NX-D15/D25/D35
NX-DX1/DX2, NX-DY1/DY2
NX-CB1
NX-CL1/CR1
NX-TL1/TR1
Built-in Serial Port
Mass Flow CMS,CMF,CMQ-V
CML,MPC,MVF
 
Sensor PBC  
Burner Controller AUR350C / 450C,RX  
Communication Convertor CMC15G,CMC10B  

YOKOGAWA*

Series CPU Ethernet Other
STARDOM FCN,FCJ Built-in Ethernet Port Built-in Serial Port
NFLR111/121
DAQSTATION
(DAQSTATION)
CX2620/2610/2420/
2410/2220
CX2210/2200/2020/
2010/2000
CX1206/1200/1006/
1000
Built-in Serial Port
NFLR111/121

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

Eurotherm*1

Series CPU Ethernet Other
Unit Controller 2500 Series *2 Built-in Ethernet Port  

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.
*2 The base unit (2500B) is required in addition for Eurotherm 2500 Series.

PANASONIC*

Series CPU Ethernet Other
Eco Power Meter KW1M(-H/R)
KW2G(-H)
KW4M, KW7M, KW8M, KW9M
  Built-in Serial Port

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

MITSUBISHI*

Series CPU Ethernet Other
Energy Monitoring Meter EcoMonitorLight   Built-in Serial Port
indicating Instrument New-S,Super-S
Smart Meter M5CM

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

HIOKI*

Series CPU Ethernet Other
Remote Measurement & Monitoring System 2300 2301/2302/2303/2304
2305/2332/2341/2342
2343/2353
 

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

Mitutoyo*

Series CPU Ethernet Other
Measurement Data Management Wireless
Communication System
"U-WAVE"
U-WAVE-R 02AZD810D   USB

* DGW-W710 is not suppoted.

Recorder

AZBIL

Series CPU Ethernet Other
Recorder SRF101/102/103/106
SRF201/202/203/206/
212/224
  Built-in Serial Port

YOKOGAWA*

Series CPU Ethernet Other
Recorder SMARTDAC+ GX10/20/60/90
GP10/20
Built-in Ethernet Port Built-in Serial Port
Recorder DXAdvanced DX1012/1006/1004/
1002(N/T)
DX2048/2040/2030/
2020/2010
DX2008/2004(T)
Recorder MVAdvanced MV1024/1012/1008/
1006/1004 MV2048/2040/2030/
2020/2010/ MV2008

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

CHINO*

Series CPU Ethernet Other
Recorder LE5000/5100/5200/5300
AH3000/AL3000
KR5100/5200/5300
KR2000/3000/BR1000
  Built-in Serial Port

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

CHINO*

Series CPU Ethernet Other
Data logging device GLT400 Series Built-in Ethernet Port  

* Accessible by MODBUS Ethernet.

Controller

AZBIL

Series CPU Ethernet Other
Digital Regulation Meter DMC50 Built-in Ethernet Port Built-in Serial Port
DMC10  
Digital Direction Regulation Meter SDC46/45/36/35/26/25/15  
Program Regulation Meter DCP31/32,DCP551/552  

Eurotherm*

Series CPU Ethernet Other
Regulation Meter nanodac Built-in Ethernet Port  

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

RKC INSTRUMENT*

Series CPU Ethernet Other
Regulation Meter PF900/901,FB100/400/900
HA430/930,SA200/201/100
RB,SRV/SRX,H-PCP-J
  Built-in Serial Port

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

CHINO*

Series CPU Ethernet Other
Regulation Meter LT230/300/350/370/
400/830
DP1000G/3000G/
DB1000
DB2000,KP1000/2000/
3000
  Built-in Serial Port

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

PANASONIC*

 
Series CPU Ethernet Other
Regulation Meter KT2/4(H/B),KT7/8/9   Built-in Serial Port

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

Network Switch

MOXA*

Series CPU Ethernet Other
Industrial Ethernet Switch EDS-828/728
EDS-518/516(A)
EDS-P510A/506
EDS-G509/500
EDS-508 /505/408/405A
Built-in Ethernet Port  

* Accessible by MODBUS Ethernet or MODBUS Serial communication.
When using Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required. DGW-W710 is not suppoted.

Sensor

OMRON*1

Series CPU Ethernet Other
Photo electric sensor     Digital Signal Wire
Analog Signal Wire
(Extension connector)
Fiber sensor  
Proximity sensor  
Laser sensor  
Dispacement sensor  
Vision sensor  
Environment sensor 2JCIE-BU01
2JCIE-BL01
  Bluetooth*2

*1 Digital input/output is compatible with DGW-F20 or DGW-W710,and analog input is compatible with DGW-F20 only.
*2 When using Bluetooth Beacon or Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required DGW-W710 is not suppoted.

 

ABLIC

Series CPU Ethernet Other
CLEAN-Boost S-CBTGAAAC   Bluetooth*

* When using Bluetooth Beacon or Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required DGW-W710 is not suppoted.

SIRC

Series CPU Ethernet Other
Angle sensor for mechanical meter PAK02   Bluetooth*

* When using Bluetooth Beacon or Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required DGW-W710 is not suppoted.

CORE

Series CPU Ethernet Other
Smell sensor Cagou-B   Bluetooth*

* When using Bluetooth Beacon or Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required DGW-W710 is not suppoted.

MURATA*

Series CPU Ethernet Other
Soil sensor SLT5009   Built-in Serial Port

* Accessible by MODBUS Ethernet or MODBUS Serial communication.

MITSUBISHI ELECTRIC*

Series CPU Ethernet Other
SineWave AE sensor YA01-SAE YA01-DPTD2-MT  

* Accessible by MODBUS Ethernet or MODBUS Serial communication.

ifm efector*

Series CPU Ethernet Other
Temperature Transmitter AL1342 Built-in Ethernet Port  

* Accessible by MODBUS Ethernet or MODBUS Serial communication.

RICOH

Series CPU Ethernet Other
RICOH EH Environment sensor D201/D202   Bluetooth*
RICOH EH CO2 sensor D101   Bluetooth*

* When using Bluetooth Beacon or Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required DGW-W710 is not suppoted.

KOBATA

Series CPU Ethernet Other
Retrofit IoT sensor unit Salta   Bluetooth*

* When using Bluetooth Beacon or Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required DGW-W710 is not suppoted.

General(I/O,Open Protocol etc.)

Each Manufacturer

Manufacturer Target device communication Protocol/Connection Type
Each Manufacturer Digital Input/Output device*1 Digital Input/Output(DI/DO)
Analog Input device*1 Analog Input(AI)
Modbus server(slave)device MODBUS/TCP(Ethernet)
MODBUS/ASCII(Ethernet)
MODBUS/RTU(Serial)
EtherNet/IP server(adapter)device BACnet/IP(Ethernet)
EtherNet/IP server(slave)device ANSI-ASHRAE Standard 135-2012 /
IEIEJ-G0006:2006(Ethernet)
IEC61850 MMS IEC61850 MMS(Ethernet)
DNP3 Outstation unit DNP3(Ethernet)
SLMP server device SLMP(Ethernet)
MTConnect Agent device MTConnect(Ethernet)
Bluetooth built-in device*2 Bluetooth Beacon
Serial I/F built-in device*2*3 Serial communication
(using User Protocol communication function)

*1 Digital input/output is compatible with DGW-F20 or DGW-W710,and analog input is compatible with DGW-F20 only.
*2 When using Bluetooth Beacon or Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required DGW-W710 is not suppoted.
*3 When using the User Protocol communication function,you can access a device that has an arbitrary ASCII communication protocol (A definition of the protcol specification is required.)

Takebishi

Manufacturer Target device communication Protocol/Connection Type
TAKEBISHI DeviceAdapter*1*2 Serial communication(via Bluetooth)

*1 When using Bluetooth Beacon or Bluetooth Serial Communication, Bluetooth conversion adapter(recommended prodect:BLED112 by Silicon Labs)is required DGW-W710 is not suppoted.
*2 When using Bluetooth Beacon or Bluetooth Serial Communication, Bluetooth conversion adapter is separately required. DGW-W710 is not suppoted.