Products

  1. TOP
  2. Products
  3. DeviceXPlorer OPC Server
  4. Support Devices
  5. FANUC CNC
  6. Support Device

Support Device

PMC-NA/NB/SA/SB/SC series

* You can scroll this table sideways.

device area device symbol Comment
PMC G (Signal from PMC to CNC)  
F (Signal from CNC to PMC)  
Y (Signal from PMC to machine)  
X (Signal from machine to PMC)  
A (Message)  
R (Internal Relay)  
T (Timer)  
K (Keep Relay)  
C (Counter)  
D (DataTable)  
CNC CML (Custom Macro Variable) Local
CMC (Custom Macro Variable) Common
CMS (Custom Macro Variable) System
STAT_AUT(AUTOMATIC mode selection)  
STAT_MAN(MANUAL mode selection)  
STAT_RUN(Status of automatic operation)  
STAT_EDT(Status of program editing)  
STAT_MOT(Status of axis movement/dwell)  
STAT_MST(Status of M/S/T/B function)  
STAT_EMG(Status of emergency)  
STAT_WRI(Status of writing backupped memory)  
STAT_LSK(Status of label skip)  
STAT_ALM(Alarm status)  
STAT_WRN(Status of warning)  
STAT_BAT(Status of battery)  
STAT_HDC(Status of manual handle re-trace)  
STAT_TMM(T/M mode selection)  
TOFS(Tool offset)  
ZOFS(Work zero offset)  
PARM(Parameter)  
ALRM(Alarm status)  
DIAG(Diagnosis)  
PATH(Path)  
AXIS_POS_ABS(Absolute position)  
AXIS_POS_MCN(Machine position)  
AXIS_POS_REL(Relative position)  
AXIS_POS_DTG(Distance to go)  
AXIS_POS_HII(Handle interruption) Input unit
AXIS_POS_HIO(Handle interruption) Output unit
AXIS_POS_SPP(Start point of program restart)  
AXIS_POS_DGP(Distance to go of program restart)  
AXIS_POS_SPB(Start point of block restart)  
AXIS_POS_DGB(Distance to go of block restart)  
AXIS_POS_FLG(Position class flags)  
AXIS_SRV_SLM(Servo load meter)  
AXIS_SRV_LCU(Load current) % unit
AXIS_SRV_LCA(Load current) Ampere unit
AXIS_SPN_SLM(Spindle load meter)  
AXIS_SPN_SMP(Spindle motor speed)  
AXIS_SPN_SSP(Spindle speed) Got from parameter
AXIS_SPN_SSS(Spindle speed) Got from motor speed
AXIS_SPN_SLA(Spindle load meter) Average
AXIS_SSP_SLM(Selected spindle load meter)  
AXIS_SSP_SMP(Selected spindle motor speed)  
AXIS_SSP_SSP(Selected spindle speed) Got from parameter
AXIS_SSP_SSS(Selected spindle speed) Got from motor speed
AXIS_SSP_SLA(Selected spindle load meter) Average
AXIS_SPD_FRF(Feed rate) F/min
AXIS_SPD_SPS(Spindle speed) S
AXIS_SPD_JDS(Jog speed/Dry run speed)  
AXIS_SPD_TTP(Tool tip speed)  
AXIS_SPD_RSS(Rotation speed of servo motor)  
AXIS_SPD_FRU(Feed speed per rotation)  
AXIS_SPD_FLG(Speed class flags)  
PRGNO_MAN(Main program number)  
PRGNO_CUR(Running program number)  
PRGNAME_MAN(Main program name)  
PRGNAME_CUR(Running program name)  
ALMDTL_NUM(Alarm number)  
ALMDTL_TYP(Alarm type)  
ALMDTL_AXS(Alarm Axis number)  
ALMDTL_MSG(Alarm message)  

 

PMC-30i series

* You can scroll this table sideways.

device area device symbol Comment
PMC G (Signal from PMC to CNC)  
F (Signal from CNC to PMC)  
Y (Signal from PMC to machine)  
X (Signal from machine to PMC)  
A (Message)  
R (Internal Relay)  
T (Timer)  
K (Keep Relay)  
C (Counter)  
D (DataTable)  
M (Input signal from the other PMC line)  
N (Output signal to the other PMC line)  
E (Extended Relay)  
CNC CML (Custom Macro Variable) Local
CMC (Custom Macro Variable) Common
CMS (Custom Macro Variable) System
STAT_AUT(AUTOMATIC mode selection)  
STAT_MAN(MANUAL mode selection)  
STAT_RUN(Status of automatic operation)  
STAT_EDT(Status of program editing)  
STAT_MOT(Status of axis movement/dwell)  
STAT_MST(Status of M/S/T/B function)  
STAT_EMG(Status of emergency)  
STAT_WRI(Status of writing backupped memory)  
STAT_LSK(Status of label skip)  
STAT_ALM(Alarm status)  
STAT_WRN(Status of warning)  
STAT_BAT(Status of battery)  
STAT_HDC(Status of manual handle re-trace)  
STAT_TMM(T/M mode selection)  
TOFS(Tool offset)  
ZOFS(Work zero offset)  
PARM(Parameter)  
ALRM(Alarm status)  
DIAG(Diagnosis)  
PATH(Path)  
AXIS_POS_ABS(Absolute position)  
AXIS_POS_MCN(Machine position)  
AXIS_POS_REL(Relative position)  
AXIS_POS_DTG(Distance to go)  
AXIS_POS_HII(Handle interruption) Input unit
AXIS_POS_HIO(Handle interruption) Output unit
AXIS_POS_SPP(Start point of program restart)  
AXIS_POS_DGP(Distance to go of program restart)  
AXIS_POS_SPB(Start point of block restart)  
AXIS_POS_DGB(Distance to go of block restart)  
AXIS_POS_FLG(Position class flags)  
AXIS_SRV_SLM(Servo load meter)  
AXIS_SRV_LCU(Load current) % unit
AXIS_SRV_LCA(Load current) Ampere unit
AXIS_SPN_SLM(Spindle load meter)  
AXIS_SPN_SMP(Spindle motor speed)  
AXIS_SPN_SSP(Spindle speed) Got from parameter
AXIS_SPN_SSS(Spindle speed) Got from motor speed
AXIS_SPN_SLA(Spindle load meter) Average
AXIS_SSP_SLM(Selected spindle load meter)  
AXIS_SSP_SMP(Selected spindle motor speed)  
AXIS_SSP_SSP(Selected spindle speed) Got from parameter
AXIS_SSP_SSS(Selected spindle speed) Got from motor speed
AXIS_SSP_SLA(Selected spindle load meter) Average
AXIS_SPD_FRF(Feed rate) F/min
AXIS_SPD_SPS(Spindle speed) S
AXIS_SPD_JDS(Jog speed/Dry run speed)  
AXIS_SPD_TTP(Tool tip speed)  
AXIS_SPD_RSS(Rotation speed of servo motor)  
AXIS_SPD_FRU(Feed speed per rotation)  
AXIS_SPD_FLG(Speed class flags)  
PRGNO_MAN(Main program number)  
PRGNO_CUR(Running program number)  
PRGNAME_MAN(Main program name)  
PRGNAME_CUR(Running program name)  
ALMDTL_NUM(Alarm number)  
ALMDTL_TYP(Alarm type)  
ALMDTL_AXS(Alarm Axis number)  
ALMDTL_MSG(Alarm message)